Table 2-2.  Switch Settings with Corresponding Base I/O Address and
Base I/O Address Space
Switch Setting
Base I/O Address
Base I/O Address
A9  A8  A7  A6  A5
(hex)
Space Used (hex)
0      0      0      0      0
000
000 - 01F
0      0      0      0      1
020
020 - 03F
0      0      0      1      0
040
040 - 05F
0      0      0      1      1
060
060 - 07F
0      0      1      0      0
080
080 - 09F
0      0      1      0      1
0A0
0A0 - 0BF
0      0      1      1      0
0C0
0C0 - 0DF
0      0      1      1      1
0E0
0E0 - 0FF
0      1      0      0      0
100
100 - 11F
0      1      0      0      1
120
120 - 13F
0      1      0      1      0
140
140 - 15F
0      1      0      1      1
160
160 - 17F
0      1      1      0      0
180
180 - 19F
0      1      1      0      1
1A0
1A0 - 1BF
0      1      1      1      0
1C0
1C0 - 1DF
0      1      1      1      1
1E0
1E0 - 1FF
1      0      0      0      0
200
200 - 21F
1      0      0      0      1
220
220 - 23F
1      0      0      1      0
240
240 - 25F
1      0      0      1      1
260
260 - 27F
1      0      1      0      0
280
280 - 29F
1      0      1      0      1
2A0
2A0 - 2BF
1      0      1      1      0
2C0
2C0 - 2DF
1      0      1      1      1
2E0
2E0 - 2FF
1      1      0      0      0
300
300 - 31F
1      1      0      0      1
320
320 - 33F
1      1      0      1      0
340
340 - 35F
1      1      0      1      1
360
360 - 37F
1      1      1      0      0
380
380 - 39F
1      1      1      0      1
3A0
3A0 - 3BF
1      1      1      1      0
3C0
3C0 - 3DF
1      1      1      1      1
3E0
3E0 - 3FF
Note:
Base I/O address values 000 through 0FF hex are reserved for  system use.  
Base I/O address values 100 through 3FF hex are  available on the I/O 
channel.
.