RuggedCom RSG2100P 用户手册

下载
页码 36
4.2  Power Supply Wiring and Grounding 
 
Figure 6: RSG2000 Series Philips Screw Terminal Block 
Philips Screw Terminal without Cover
Philips Screw Terminal with Cover
Safety Cover
Safety Cover 
Screws
Chassis Ground 
Connection
Surge / Chassis 
Ground Jumper
Terminal
 
Figure 7: RSG2000 Series Phoenix Plug Terminal Block 
Phoenix Plug Terminal without Cover
Phoenix Plug Terminal with Cover
Safety Cover 
Screws
Safety Cover
Chassis Ground 
Connection
Terminal
Surge / Chassis 
Ground Jumper
 
The RSG2100P supports a single AC or DC power supply, “Power Supply 1 (PS1)” and a separate 
48VDC power supply, “Power Supply 2 (PS2)” used to provide the power over Ethernet. The 
connections for PS1, PS2 and the fail-safe relay are located on the terminal block as shown in 
The RSG2000 Family chassis ground connection, shown in Figure 8, uses a #6-32 screw. It is 
recommended to terminate the ground connection in a #6 ring lug, and to use a torque setting not 
exceeding 15 in.lbs (1.7 Nm). 
 
 
Figure 8: Chassis Ground Connection 
#6 ring lug 
stainless steel standoff
#6-32 screw with 
ext. washer. 
13 
© 
2008 RuggedCom Inc.  All rights reserved 
 
Rev105