Ethernet Statistics 
RS400 
121 
ROS™  v3.5 
 
Figure 84: RMON History Controls Form 
 
Index 
Synopsis: 1 to 65535 
Default: 1 
The index of this RMON History Control record. 
Port 
Synopsis: 1 to maximum port number 
Default: 1 
The port number as seen on the front plate silkscreen of the switch. 
Requested Buckets 
Synopsis: 1 to 4000 
Default: 50 
The maximum number of buckets requested for this RMON collection history group of statistics. 
The range is 1 to 4000. The default is 50. 
Granted Buckets 
Synopsis: 0 to 65535 
The number of buckets granted for this RMON collection history. This field is not editable. 
Interval 
Synopsis: 1 to 3600 
Default: 1800 
The number of seconds in over which the data is sampled for each bucket. The range is 1 to 