12.5  Loading Factory Default Configuration 
The Load Factory Default Configuration option will reset all configuration parameters to factory 
default values with the exception of parameters that affect basic connectivity and SNMP 
management. Specifically, configuration items in the following categories are not reset by this 
operation: 
• IP 
Interfaces 
• IP 
Gateways 
• SNMP 
Users 
•  SNMP Security to Group Maps 
• SNMP 
Access 
 
A prompt message will be displayed requesting confirmation of this action. 
 
Figure 170: Load Factory Defaults Dialog 
 
Note:  It is possible to explicitly reset configuration items in the exceptional categories listed above to their 
default values by using the “sql” command. Please refer to the section entitled: “Upgrading 
Firmware and Managing Configurations”. 
12.6  Resetting the Device 
This operation will close all open Telnet connections and warm start the device after User has 
confirmed the reset operation from the Reset Device option.