RuggedCom RS400 用户手册

下载
页码 275
 
 
Appendix B – SNMP Trap Summary 
RS400 
261 
ROS™  v3.5 
Appendix B – SNMP Trap Summary 
The switch generates the standard traps summarized in the following table. 
•  from IF-MIB: linkDown, linkUp 
•  from SNMPv2-MIB: authenticationFailure coldStart 
•  from BRIDGE-MIB: newRoot, topologyChage 
•  from RMON-MIB: risingAlarm, fallingAlarm 
•  from LLDP-MIB: lldpRemoteTablesChange 
 
The switch also generates the proprietary traps which are summarized in this document with 
their severity levels.  These traps are described in the RC-TRAPS-MIB. 
•     genericTrap, 
•     powerSupplyTrap, 
•     swUpgradeTrap, 
•     cfgChangeTrap 
 
Generic Traps carry information about event in severity and description objects. They are sent 
at a time when alarm is generated for device. Here are some examples when RuggedCom 
Generic Traps are generated: 
•  heap error (alert) 
•  NTP server failure (notification) 
•  real time clock failure (error) 
•  failed password (warning) 
•  MAC address not learned by switch fabric (error) 
•  BootP client: TFTP transfer failure (error) 
•  received looped back BPDU (error) 
•  received two consecutive confusing BPDUs on port, forcing down (error)  
•  GVRP failed to learn – too many VLANs (warning)