RuggedCom RS400 用户手册

下载
页码 275
Serial Protocols 
 
 
ROS™  v3.5 
54 
RS400 
•  TCP accept one dynamic connection from different IP address 
•  Dynamic connection activity timer controlled 
•  XON/XOFF flow control for permanent connection 
•  ‘Packetization’ trigger based on a full packet, a specific character or upon a timeout for each 
connection 
 
2.1.3   ‘Modbus’ protocol features 
•  Operation in TCPModbus server gateway or client gateway mode 
•  Multi-master mode on server 
•  Configurable behavior in for sending exceptions 
•  Full control over ‘packetization’ timers 
•  Configurable Auxiliary IP port number for applications that do not support port 502 
 
2.1.4 ‘DNP’ protocol features 
•  ‘Packetization’ per protocol specification 
•  CRC checking in message headers received from the serial port 
•  Local and remote source address learning 
 
2.1.5   ‘Microlok’ protocol features 
•  ‘Packetization’ per protocol specification 
 
2.1.6   ‘WIN’ protocol features 
•  ‘Packetization’ following the protocol requirements 
•  CRC checking for messages received from the serial port 
 
2.1.7   ‘TIN’ protocol features 
•  Support for two modes of TIN protocol 
•  ‘Packetization’ following the protocol requirements 
•  CRC checking for messages received from the serial port 
•  Remote source address learning, specific for two different modes