2.8.2  GBIC Module Removal 
 
GBIC Modules have two locking latches, one on either side of the module, as 
shown in Figure 27. To remove a GBIC module, disconnect any cables and 
replace the dust cover to protect the optics. Depress both latches simultaneously 
and gently pull the module from the chassis. The module should be immediately 
stored in an ESD-safe environment. 
 
 
Figure 27: Locking latch location on GBIC optical modules 
 
2.8.3  SFP Module Removal 
 
SFP Modules are removed using the metal bail latch located on the top of the 
module as shown in Figure 28. To remove the SFP module, disconnect any 
cables and replace the dust cover to protect the optics. Grasp the bail latch and 
gently pull outwards to unlock and remove the module. Removal of an SFP 
module is shown further in Figure 29. The module should be immediately stored 
in an ESD-safe environment. 
 
 
 
 
Figure 28: SFP Bail Latch location 
Figure 29: SFP Removal 
 