RuggedCom RS920W 用户手册

下载
页码 8
www.RuggedCom.com
5
RuggedWireless™ RS920W
RuggedWireless
TM
RS920W
Wireless Serial Device Server with Ethernet over VDSL Interface
EMI and Environmental Type Tests
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40°C, 16 Hours
N/A
IEC 60068-2-2
Dry Heat
Test Bd
+85°C, 16 Hours
N/A
IEC 60068-2-30
Humidity (Damp Heat, Cyclic)
Test Db
95% (non-condensing), 
55°C , 6 cycles
N/A
IEC 60255-21-1
Vibration
Tests Fc
2g @ (10 - 150) Hz
Class 2 
1
IEC 60255-21-2
Shock
Tests Ea
30g @ 11mS
Class 2
IEC 61000-6-2 EMC Generic Standard:  Immunity for Industrial Environments
Test
Description
Levels
RuggedCom Test Level
Performance Criteria*
IEC 61000-4-2
ESD
Enclosure Contact
+/- 4kV
+/- 8kV
B
Enclosure Air
+/- 8kV
+/- 15kV
B
IEC 61000-4-3
Radiated RFI
Enclosure ports
10 V/m, 80 to 1000Mhz
20V/m
A
IEC 61000-4-4
Burst (Fast Transient)
Signal ports
+/- 1kV @ 5kHz
+/- 4kV @ 2.5kHz
B
D.C Power ports
+/- 2kV @ 5kHz
+/- 4kV
B
A.C. Power ports
+/- 2kV @ 5kHz
+/- 4kV
B
IEC 61000-4-5
Surge
Signal ports
+/- 1kV line-to-earth
+/- 2kV line-to-earth, +/- 2kV
line-to-line
B
D.C Power ports
+/- 0.5kV line-to-earth/line
+/- 4kV line-to-earth, +/- 2kV
line-to-line
B
A.C. Power ports
+/- 2kV line-to-earth, +/- 1kV
line-to-line
+/- 4kV line-to-earth, +/- 2kV
line-to-line
B
IEC 61000-4-6
Induced (Conducted) RFI
Signal ports
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
A
D.C Power ports
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
A
A.C. Power ports
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
A
Earth ground ports
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
A
IEC 61000-4-8
Magnetic Field
Enclosure ports
30 A/m @ 50, 60 Hz
40 A/m continuous, 1000
A/m for 1s
A
IEC 61000-4-11
Voltage Dips
A.C. Power ports
30% reduction for 0.5 
period
30% for 1 period
B
>95% reduction for 250
periods
100% for 5 periods, 100%
for 50 periods
C
IEC 60255-5
Dielectric Strength
Signal ports
2kVac 
(Fail-Safe Relay output)
2kVac
(Fail-Safe Relay output)
N/A
D.C. Power ports
2kVac 
2kVac 
N/A
A.C. Power ports
2kVac 
2kVac 
N/A
IEC 60255-5
H.V. Impulse
Signal ports
5kV
(Fail-Safe Relay output)
5kV
(Fail-Safe Relay output)
N/A
D.C. Power ports
5kV 
5kV 
N/A
A.C. Power ports
5kV 
5kV 
N/A
Notes: 1. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")
NEMA TS-2 Requirements
Test
Description
Levels
Performance Criteria*
TS-2 1998, Section 2, para 2.2.7.3
Temperature:  Low Temperature/Low
Voltage
89.0 VAC @ -34°C
EUT Continued to function properly during
and following all temperature and humidity
testing
TS-2 1998, Section 2, para 2.2.7.4
Temperature:  Low Temperature/High
Voltage
135.0VAC @ -34°C
TS-2 1998, Section 2, para 2.2.7.5
Temperature:  High Temperature/High
Voltage
135.0VAC @ + 75°C
TS-2 1998, Section 2, para 2.2.7.6
Temperature:  High Temperature/Low
Voltage
89.0VAC @ + 75°C
TS-2 1998, Section 2 para. 2.2.8.4
Vibration Endurance Test
0.5g @ 30Hz for 1hr on all three planes
EUT functioned properly following test pro-
cedure.  No physical damage.
TS-2 1998, Section 2, para 2.1.10
Mechanical Shock
+/-10g half sine wave for 11msec on all
three planes
EUT functioned properly following test pro-
cedure.  No physical damage.
TS-2 1992, Section 2, para. 2.1.6.1
Electrical Transients: High Repetition Noise
(AC Terminals)
One +/-300VDC pulse every other cycle
once every 3 seconds across 360 ° of line
cycle (2500W peak)
EUT functioned properly during and follow-
ing test procedure.  No damage
TS-2 1998, Section 2 para. 2.1.6.2
Electrical Transients:  Low-Repetition High
Energy (AC Terminals
One +/-600VDC pulse every second, ran-
domly distributed across 360 ° of line
cycle.  Ten pulses total.
EUT functioned properly during and follow-
ing test procedure.  No damage
TS-2 1998, Section 2, para 2.1.7
Electrical Transients:  I/O Terminals
One +/-300VDC pulse every second, mini-
mum 5 pulses per port
EUT functioned properly during and follow-
ing test procedure.  No damage
TS-2 1992, Section 2, para. 2.1.8
Electrical Transients: Nondestruct
Transient Immunity (AC Terminals)
One +/-1000VDC pulse every two seconds,
3 per each polarity.
EUT functioned properly following test pro-
cedure.  No damage