Omega Engineering PSW1000 用户手册

下载
页码 8
Dimensions (in mm)
3
1. Product Description
2.  Starting operations
Electrical connections plug 1 (standard) and power supply
Intended Applications
-
The dual pressure switch is a device to monitor system pressure
and has up to two switching outputs and one analog output.
-
The instruments must only be installed in systems where the
maximum pressure Pmax or the maximum temperature Tmax is
not exceeded (according to the values on the type label).
-
Attention: This device is not designed to be used as the only
safety relevant element in pressurized systems according PED
97/23/EC.
Only assemble or disassemble the device when depressurized!
Connecting the switch
-
Mount the pressure switch from bottom to the fitting with a wrench hex 19 (1/4“) resp. hex 22
with 45 Nm torque.
-
Electrical connection depends on the type of pressure switch (see type label) according to the
chart below (connection chart plug 2 for interface see page 4).
-
When display is adjusted (rotable version only) the unit has to be fixed at the front side with
an allen screw and and allen key 1,5 mm (torque = 3 Nm).
Plug
M 12 x 1
4-pin / 5-pin
PG9 with cable
LifYY11Y
4 / 5x0,25mm
2
Model with 1
switching 
output
Model with 2
switching 
outputs
Model with 1
switching output
and 1 analog output
Model with 2
switching outputs
and 1 analog output
Pin 1
Brown
18...32 V DC 18...32 V DC 18...32 V DC
18...32 V DC
Pin 2
White
-
SP2 0,5 A
max.
analog 4...20 mA/
0...10 V DC
analog 4...20 mA/
0...10 V DC
Pin 3
Blue
0 V
0 V
0 V
0 V
Pin 4
Black
SP1 0,5 A
max.
SP1 0,5 A
max.
SP1 0,5 A max.
SP1 0,5 A max.
Pin 5
Grey
-
-
-
SP2 0,5 A max.
PSW1000
PSW1000.qxp  6/5/2008  3:45 PM  Page cov-5