Rack-mounting
23
Water or moisture cannot enter the case of the Switch.
Air flow is not restricted around the Switch or through the vents in the 
side of the Switch. 3Com recommends that you provide a minimum of 
25mm (1in.) clearance.
Air temperature around the Switch does not exceed 40 
°C
 (104 
°
F).
If the Switch is installed in a 19-inch rack or closed assembly its local air 
temperature may be greater than room ambient temperature.
The air is as free from dust as possible.
The unit is installed in a clean, air conditioned environment.
No more than four Switch units are placed on top of one another, if 
the units are free-standing.
The Switch is situated away from sources of conductive (electrical) 
dust, for example laser printers.
The AC supply used by the Switch is separate to that used by units 
that generate high levels of AC noise, for example air conditioning 
units and laser printers.
Rack-mounting
The Switch 4200G is 1 rack unit (1U) high and will fit in most standard 
19-inch racks. 
CAUTION: Disconnect all cables from the Switch before continuing. 
Remove all self adhesive pads from the underside of the Switch if they 
have been fitted.
To rack-mount your Switch:
Place the Switch the right way up on a hard flat surface, with the front 
facing towards you.
Locate a mounting bracket over the mounting holes on one side of the 
front of the Switch, as shown in Figure 5.
You can also rack mount your Switch using the mounting holes at the 
rear of the Switch.