sensorShow
Display sensor readings.
Syntax
sensorShow
Availability
All users
Description
Use this command to display the current temperature, fan and power 
supply status and readings from sensors located on the switch. The 
actual location of the sensors varies depending on the switch type.
In the ED-12000B, the information returned with 
sensorShow
 is 
specific to the logical switch you are logged in to:
If you are logged in to Logical switch 0, sensors 1 through 4 are 
for switch blade slots 1 through 4, respectively. Sensors 5 and 6 
are for the two CPs in slots 5 and 6, respectively.
If you are logged in to Logical switch 1, sensors 1 and 2 are for the 
two CPs in slots 5 and 6, respectively. Sensors 3 through 6 are for 
switch blade slots 7 through 10, respectively.
If you are logged in to the Active CP through the console port, 
you are prompted to specify the logical switch this command is 
executed on. If you log in to the Active CP through the Fabric OS 
shell, this command always executes on the default switch 
(logical switch 0).
Regardless of logical switch, sensors 7 through 9 are for the three 
chassis fans, left to right, and sensors 10 through 13 are for the 
four chassis power supplies, bottom to top.