If you require the voltage setting to be 
altered, e.g. relocation to another area, city or 
country, or extraordinarily high or low 
voltages, contact your Perreaux dealer.  This 
modification must only be performed by 
qualified service personnel. 
 
Note: Always ensure the unit is disconnected 
from the Mains/Line supply before any covers 
are removed. 
 
MAINS/LINE FUSE
 
 
The Perreaux 200P is equipped with a user 
serviceable mains/line fuse.  Above the 
mains/line cord is the mains/line fuse holder.  
In the unlikely event of fuse failure always 
replace with the same type and value fuse.  
Remember, fuses do not usually blow without 
a reason.  Any doubts about fuse failure 
should be conveyed directly to your Perreaux 
dealer. 
 
The fuse ratings are: 
  100-125V 2SB SLOW BLOW 8A 
 Continuous 
  200-250V 2SB SLOW BLOW 6A 
 Continuous 
Note: Always ensure your 200P is 
disconnected from the Mains/Line supply 
before attempting to change the Mains/Line 
fuse. 
 
RAIL FUSES 
 
The Perreaux 200P has 4 internal fuses for 
amplifier protection. In the unlikely event of 
internal fuse failure consult your Perreaux 
dealer. The internal fuses are not user 
serviceable
 and only authorised personnel 
may replace the internal fuses. 
 
Fuse Rating -3AG Normal Acting 6 Amp 
 
SERIAL NUMBER 
 
All Perreaux units are allocated a unique 
serial number which are recorded at the 
factory against build details. If you should 
require information about your unit, providing 
the serial number will help achieve a prompt 
reply.Keep a copy of all your serial numbers 
in a safe place.  The ability to identify and 
prove ownership can be very useful.
 
 
SPECIFICATIONS 
 
 
Tested at 120 / 220 / 230 / 240V ac 
mains voltage after initial 10 minute warm 
up period 
 
 
 POWER 
OUTPUT 
 
200 watts RMS per channel continuous 
both channels driven into 8
Ω
 from 20Hz 
to 20kHz at no more than 0.02% THD 
 
 
300 watts RMS into 4
Ω
 
 FREQUENCY 
RESPONSE 
 
±
 0.25dB from 20Hz to 20kHz 
 
 
TOTAL HARMONIC DISTORTION 
 
0.02% THD worst case prior to clipping 
 
0.004% THD @ 1KHz 
 
 HUM, 
NOISE 
 
-95dB unweighted referenced to rated 
output 
 
 INPUT 
SENSITIVITY 
 
Balanced 0.6V 
RMS 
 
Unbalanced 1.2V RMS 
 
 INPUT 
IMPEDANCE 
 Balanced 
 
3.3k
Ω
 
 Unbalanced 
22k
Ω
 
 
 DYNAMIC 
HEADROOM 
 1.9dB 
 CURRENT 
OUTPUT 
 
24 Amperes peak per channel 
 
 DRIVER 
STAGE 
 Class 
 
 OUTPUT 
STAGE 
 
Class A / AB 
 
DIMENSIONS (not including handles and 
terminals) 
 
 
HEIGHT  x  WIDTH  x  DEPTH
 
 
88mm x 482mm x 460mm 
 
3.5" x 19.0" x 18.1" 
 
 NETT 
WEIGHT 
 17.0kg 
(37.5lb)