Sun Microsystems 5602 用户手册

下载
页码 324
4 – Managing Switches
Displaying Switch Information
4-10
59097-01 A
0
Zoning Default Visibility
Zoning visibility status. Permits (All) or prevents (None) 
communication between attached devices in the absence 
of an active zone set.
Security Auto Save
N/A - does not apply to this switch
Security Fabric Binding 
Enable
N/A - does not apply to this switch
Temperature
Internal switch temperature °C
Fan 1 Status
The status of Fan 1 
Fan 2 Status
The status of Fan 2
Fan 3 Status
N/A - does not apply to this switch
Power Supply 1 Status
Power supply 1 status
Power Supply 2 Status
Power supply 2 status
Beacon Status
Beacon status. Switch LEDs are blinking (On) or not (off).
Broadcast Support
Broadcast support status. Broadcast support is enabled or 
disabled (default).
In-band Enabled
In-band management status. Permits (True) or prevents 
(False) a switch from being managed over an ISL.
Temperature Failure Port 
Shutdown 
Non-configurable (always enabled for this switch). All 
ports are downed when the switch temperature exceeds 
the Failure Temperature.
Warning Temperature
Non-configurable temperature threshold (65° Celsius) 
above which a warning condition alarm is generated.
Failure Temperature
Non-configurable temperature threshold (70° Celsius) 
above which a failure condition alarm is generated.
NTP Client Enabled
Enabled or disabled. Allows for switches to synchronize 
their time a centralized server. 
NTP Server Address
The IP address of the centralized NTP server. Ethernet 
connection to NTP server is required. 
FDMI HBA Entry Limit
Maximum number of HBAs that can be registered with a 
switch.
Table 4-2. Switch Data Window Entries  (Continued)
Entry
Description