4 – Managing Switches
Paging a Switch
59097-01 A
4-15
0
5.
Enter a value for the rising trigger. A rising trigger alarm is generated when 
the event count per interval exceeds the rising trigger. The switch will not 
generate another rising trigger alarm for that event until the count descends 
below the falling trigger and rises again above the rising trigger. Consider 
the example in 
6.
Enter a value for the falling trigger. A falling trigger alarm is generated when 
the event count per interval descends below the falling trigger.
Figure 4-8.  Port Threshold Alarm Example
7.
Enter a sample window in seconds. The sample window defines the period 
of time in which to count events.
8.
Repeat steps 3 through 7 for each alarm you want to configure or enable. 
9.
Click the OK button to save all changes.
4.4
Paging a Switch
You can use the beacon feature to page a switch. The beacon feature causes all 
Logged-In LEDs to flash, making it easier to recognize. To page a switch, open 
the Switch menu in the faceplate display and enable the Toggle Beacon 
selection. To cancel the beacon, reselect Toggle Beacon.
Note:
The switch will down a port if a rising trigger alarm is not cleared 
after three consecutive sample windows.