4 – Managing Switches
Configuring a Switch
4-24
59097-01 A
0
4.7.3.2
Legacy Port Address Format
Legacy Address Format should be enabled only to permit interoperation with 
certain older non-FC-SW-2 compliant switches. Enabling this setting under other 
circumstances will disable zoning that is defined by domain ID and port number. 
This Legacy Address Format option is available only when the Interop_1 setting is 
enabled on the Advanced Switch Properties dialog. Contact your authorized 
maintenance provider for assistance in using this feature. Refer to the QLogic 
Switch Interoperability Guide on the QLogic Web site for a complete discussion of 
configuring for operation with non-Qlogic Switches.
4.7.3.3
Timeout Values
The switch timeout values determine the timeout values for all ports on the switch. 
 describes the switch timeout parameters. The timeout values must be 
the same for all switches in the fabric.
Note:
The Legacy Address Format setting must be the same on all switches 
in the fabric, otherwise the inter-switch links will not connect.
Note:
Mismatched timeout values will disrupt the fabric. These should not be 
changed unless absolutely necessary. Therefore, the switch must be 
offline to change these values. Use the Switch Properties dialog to take 
the switch offline.
Table 4-5. Timeout Values
Parameter
Description
R_A_TOV
Resource Allocation Timeout: Represents the maximum time a frame 
could be delayed in the Fabric and still be delivered. The default is 
10000 milliseconds.
E_D_TOV
Error Detect Timeout: Represents the maximum round trip time that 
an operation between two N_Ports could require. The default is 2000 
milliseconds.