Test Command
59097-01 A
A-119
0
Test Command
Tests ports using internal (SerDes level), external (transceiver), and online 
loopback tests. Internal and external tests require that the port be placed in 
diagnostic mode. Refer to the 
 for information about 
changing the port administrative state. While the test is running, the remaining 
ports on the switch remain fully operational.
Authority
Admin session
Syntax
test
port [port_number] [test_type]
cancel
status
Keywords
port [port_number] [test_type]
Tests the port given by [port_number] using the test given by [test_type]. If you 
omit [test_type], Internal is used. [test_type] can have the following values:
internal
Tests the SerDes for all port speeds independent of the capabilities of the 
transceiver. This is the default. The port must be in diagnostics mode to 
perform this test.
external
Tests both the SerDes and transceiver for all port speeds that are supported 
by the transceiver. The port must be in diagnostics mode to perform this test, 
and a loopback plug must be installed in the transceiver.
online
Tests communications between the port and its device node or device loop 
at the operating port speed. The port being tested must be online and 
connected to a remote device. The port passes if the test frame that was 
sent by the ASIC matches the frame that is received. This test does not 
disrupt communication on the port.
cancel
Cancels the online test in progress.
status
Displays the status of a test in progress, or if there is no test in progress, the 
status of the test that was executed last.
Note:
An internal test on a 10-Gbps port verifies that a complete path 
exists, but does not send a test frame.
Note:
An external test on a 10-Gbps port verifies that a complete path 
exists, but does not send a test frame.