Chapter 2
Configurations
9
Sun StorEdge A5000 and A5100 arrays are not supported.
TABLE 2-2
Sun StorEdge A5200 Array
Feature
Supported
Cascading
No
Zone type
SL zone only
Maximum number of arrays per SL zone
3
Maximum initiators per SL zone
2
Maximum initiators per array
4 (2 per loop)
Split loop support
No
TABLE 2-3
Sun StorEdge T3 Array and T3+ Array
Feature
Supported
Cascading
Yes
Zone Type
nameserver zone
1
, SL zone
1. The host must be connected to the F-Port on the switch; Sun StorEdge T3 array must be connected to the TL port
of the switch.
Maximum number of arrays per zone
8
Maximum initiators per LUN
2
Maximum initiators per zone
2
2
2. This implies 2 initiators (2 hosts) for simple arrays (T3WG), but 4 initiators (2 hosts) for a partner pair (T3ES).
Each host has one path to each of the Sun StorEdge T3 arrays in the partner pair.