Avaya C460 用户手册
Chapter 2 Avaya C460 CLI Commands
Avaya C460 Reference Guide
75
rmon alarm
User level: read-write, admin.
Use the rmon alarm command to create a new RMON alarm entry.
Use the rmon alarm command to create a new RMON alarm entry.
The syntax for this command is:
rmon alarm
<Alarm Number> <variable> <interval> <sampletype>
rising-threshold
<rising threshold> <rising event> falling-
threshold
<falling threshold> <falling event> <startup alarm>
<owner>
Example:
alarm number
This is the alarm index number of this entry (it is advisable to
use the same interface number as your alarm index number.)
use the same interface number as your alarm index number.)
variable
This is the MIB variable which will be sampled by the alarm
entry.
entry.
interval
The interval between 2 samples.
sample type
This can be set to either delta (the difference between 2
samples) or an absolute value.
samples) or an absolute value.
rising threshold
This sets the upper threshold for the alarm entry.
rising event
The RMON event entry that will be notified if the upper
threshold is passed.
threshold is passed.
falling
threshold
threshold
This sets the lower threshold for the alarm entry.
falling event
The RMON event entry that will be notified if the lower
threshold is passed.
threshold is passed.
startup alarm
The instances in which the alarm will be activated. The
possible parameters are: Rising, Falling, risingOrfalling.
possible parameters are: Rising, Falling, risingOrfalling.
owner
Owner name string.
C460-1# rmon alarm 1026 1.3.6.1.2.1.16.1.1.1.5.1026 60
delta rising-threshold 10000 1054 falling-threshold 10 1054
risingOrFalling gregory
alarm 1026 was created successfully