4.3.1.1.1 On CD-RW media
The media is formatted using Write Parameter Mode Page information. Some parameters in the Write Parameter Mode Page shall be
set as follows;
Test Write = 0, Write Type = 0h, FP = 1, Track Mode = 01x1b, Data Block Type = 8h or Ah,
Session Format = 00h or 20h, Packet Size = 20h
set as follows;
Test Write = 0, Write Type = 0h, FP = 1, Track Mode = 01x1b, Data Block Type = 8h or Ah,
Session Format = 00h or 20h, Packet Size = 20h
This format operation is always available regardless of the media condition.
4.3.1.1.2 On DVD-RW media
The media is inserted in the drive, the area from the beginning of the RMA to the end of the Lead-out will be recorded. There is only
one bordered area on the medium and the number of RZone is one after this operation.
one bordered area on the medium and the number of RZone is one after this operation.
The Test Write bit in the Write Parameters Mode Page shall be set to zero.
This format operation is available on any recording mode and any state of a bordered area.
4.3.1.2 Format Type = 10h (C/DVD -RW Full Format)
Formatting to create a Session/Border on C/DVD-RW media is specified.
If the Immed function is set to zero, the drive will return the status after the format operation has completed. If the Immed bit is set to
one, the drive will return the status as soon as the command descriptor block has been validated, and the entire Format Descriptor has
been transferred.
one, the drive will return the status as soon as the command descriptor block has been validated, and the entire Format Descriptor has
been transferred.
The READ DISC INFORMATION Command, the READ TRACK/RZONE INFORMATION Command and the TEST UNIT
READY Command is used to detect completion of the format operation. While format operation is performed by the FORMAT
UNIT Command that the Immed function is set to one, the drive terminates these commands with the Check Condition status,
LOGICAL UNIT NOT READY, FORMAT IN PROGRESS (2/04/04). If the drive returns Good status for these command, format
operation has completed.
READY Command is used to detect completion of the format operation. While format operation is performed by the FORMAT
UNIT Command that the Immed function is set to one, the drive terminates these commands with the Check Condition status,
LOGICAL UNIT NOT READY, FORMAT IN PROGRESS (2/04/04). If the drive returns Good status for these command, format
operation has completed.
In response to the REQUEST SENSE command, including after the Check Condition status described above, the drive will return a
SK/ASC/ASCQ values set to NOT READY/LOGICAL UNIT NOT READY/FORMAT IN PROGRESS, with the sense key specific
bytes set for progress indication. The SKSV will be set to one and the Progress Indication field will contain 16 bit unsigned value such
that (Progress Indication)/65 536 X 100% approximates the percentage of completion of the operation. Once the operation is
completed, the SKSV will be cleared to zero.
SK/ASC/ASCQ values set to NOT READY/LOGICAL UNIT NOT READY/FORMAT IN PROGRESS, with the sense key specific
bytes set for progress indication. The SKSV will be set to one and the Progress Indication field will contain 16 bit unsigned value such
that (Progress Indication)/65 536 X 100% approximates the percentage of completion of the operation. Once the operation is
completed, the SKSV will be cleared to zero.
4.3.1.2.1 On CD-RW media
The created Session will become the only Session on the medium. The Number of Blocks field specifies the number of addressable
blocks for the new Session and the Type Dependent Paramet er field specifies the Fixed Packet Size (32). The Number of Blocks field
may be adjusted to a value less than or equal to the values reported by the READ FORMAT CAPACITIES Command. The drive will
round the Number of Blocks up to be an integral multiple of the packet size.
Some parameters in the Write Parameter Mode Page shall be set as follows;
Test Write = 0, Data Block Type = 8h or Ah, Session Format = 00h or 20h
After the FORMAT UNIT command is received by the drive, some parameters in the Write Parameter Mode Page will be modified as
follows;
Write Type = 0h, FP = 1, Track Mode = 01x1b, Packet Size = 20h
blocks for the new Session and the Type Dependent Paramet er field specifies the Fixed Packet Size (32). The Number of Blocks field
may be adjusted to a value less than or equal to the values reported by the READ FORMAT CAPACITIES Command. The drive will
round the Number of Blocks up to be an integral multiple of the packet size.
Some parameters in the Write Parameter Mode Page shall be set as follows;
Test Write = 0, Data Block Type = 8h or Ah, Session Format = 00h or 20h
After the FORMAT UNIT command is received by the drive, some parameters in the Write Parameter Mode Page will be modified as
follows;
Write Type = 0h, FP = 1, Track Mode = 01x1b, Packet Size = 20h
This format operation is always available regardless of the media condition.
4.3.1.2.2 On DVD-RW media
The created Border will become the only Border on the medium. The Number of Blocks field specifies the number of addressable
blocks for the new Border and the Type Dependent Parameter field specifies the ECC block size (16). The Number of Blocks field
may be adjusted to a value less than or equal to the values reported by the READ FORMAT CAPACITIES Command. The drive will
round the Number of Blocks up to be an integral multiple of the ECC block size.
blocks for the new Border and the Type Dependent Parameter field specifies the ECC block size (16). The Number of Blocks field
may be adjusted to a value less than or equal to the values reported by the READ FORMAT CAPACITIES Command. The drive will
round the Number of Blocks up to be an integral multiple of the ECC block size.
The Test Write bit in the Write Parameters Mode Page shall be set to zero.
This format operation is available on any recording mode and any state of a bordered area. The number of RZone in the created Border
is one after this operation.