Saving and restoring configuration settings
The ServSwitch CX can store up to 512 server names and 16 sets of user access 
rights (ServSwitch CX with IP models support a maximum of 128 servers). 
Particularly in cascaded configurations, manually re-entering all server names, 
port numbers and access rights can be a lengthy process. Therefore, the 
ServSwitch CX provides a method to save and, if required, restore configuration 
settings using one of its serial ports. Further to this, the saved file can be opened 
and edited within a spreadsheet and then restored back to the ServSwitch CX 
– a useful way to make multiple setup changes. 
Note: You must be logged-in as the ADMIN user for this procedure. 
Preparations for configuration save/load 
•  Contact Black Box support and obtain the files XPREAD.EXE and XPWRITE.
EXE.
•  Connect the serial port on the rear panel of the ServSwitch CX, labelled 
COM1/UPGRADE
, to a serial port on your server using the optional serial 
flash upgrade cable available from Black Box. See 
 for pin-out 
specifications. 
To save configuration settings
1  Run the program XPREAD.EXE on the server that is connected to the 
ServSwitch CX’s serial port. Follow the instructions given by the program.
2  Using one of the ServSwitch CX user ports, display the 
Note: You must be logged-in as the ADMIN user.
3  Highlight ‘Functions’ and press 
.
4  Highlight ‘Send Data to RS232 port’ and press 
.
5  The ServSwitch CX will send the configuration data to your server. The 
XPREAD program will store the data in a file named ‘XPRODATA.CSV’ that 
will be created in the same directory where the XPREAD program was 
started - Ensure that you have sufficient rights to write to this directory.
To edit the configuration settings
The saved XPRODATA.CSV file can be opened using a spreadsheet program such 
as Microsoft® Excel®. The format of a typical file is shown below. You will see 
that the server names (rows) are tabulated against the user profiles (columns):
USERS  
 
ADMIN  
Alan  
Jim  
Sue  
Test
PASSWORDS  
 
password   letmein   hello   logmein   Test
ServerS  
PORT
Admin PC  
2103  
1  
1  
1  
1
Alan’s System  
2102  
1  
1  
Comms Server  
3  
1  
 
1
Comms PC  
4  
1  
1  
1  
1
Gateway 1 
8  
1
Gateway 2 
5  
1
Test System  
15  
1  
1
Web Browser  
9  
1  
 
 
Hints for editing
•  To grant a user access to a server, enter the value ‘1’ in the box that is 
common to the server’s row and the user’s column. 
•  To deny access, leave the box blank. 
•  To add extra users, add additional columns (up to 16 users). 
•  To add extra servers, add additional rows (up to 512 [128 for IP models]). 
•  The ADMIN user will always be granted access to all servers regardless of the 
values entered.
To restore configuration settings
Note: Ensure that the server is connected to the ServSwitch CX as discussed 
earlier in the ‘Preparations’ sub section. 
1  Copy the program XPWRITE and XPRODATA.CSV into the same directory on 
the server connected to the ServSwitch CX’s serial port.
2  Run the program XPWRITE.EXE and follow the instructions given by the 
program.
3  Using one of the ServSwitch CX user ports, display the 
Note: You must be logged-in as the ADMIN user.
4  Highlight ‘Functions’ and press 
.
5  Highlight ‘Read Data from RS232 port’ and press 
.
6  The ServSwitch CX should then receive the configuration data from the 
server and load the new menu names and access rights into the menu.