Renumbering the Phantom Remotes 
 
5-1
Chapter 5: Renumbering the Phantom Remotes 
When the Phantom system was first installed, ID numbers were assigned with the auto-numbering process. 
Auto numbering gives each Phantom Remote a sequential number according to its physical location in the 
daisy chain. Remote units can be renumbered according to their physical location or by manually choosing the 
numbers you desire.  
Renumbering is done using Phantom Numbering software. The software is on the Marketing & Documentation 
CD. 
Connecting the Phantom System 
To renumber the Remotes the Phantom system must be connected and switched on.  
Connecting the RS232 Serial cable 
To run the software, connect the RS232 Serial cable to the computer containing the software, and to the 
Phantom Manager. See chapter 5 of the Installation guide. 
RS232 Serial cable system requirements 
•  Pentium 166 or higher computer 
•  16Mb RAM 
•  Windows 98, NT4 (SP6), 2000, ME or XP  
•  Free Serial port 
Running the Phantom Numbering software 
To use the Numbering software, the OSD must be in the Numbering mode.  
1. Press 
ShiftShift to display the OSD. 
2. Press 
F10 to enter the Numbering mode. The Firmware Upgrade label appears. See Figure 
 
Figure 
 
5-1 The Firmware Upgrade label 
Start the Marketing & Documentation CD and choose Phantom Utilities Softpack. The Phantom Softpack 
window appears. The Numbering Software can be installed onto the computer or operated directly from the 
CD. To install the software choose Install Phantom Numbering Software
To run the software: 
Select Run Phantom Numbering Software. The Phantom Numbering window appears. See Figure 
 
Figure 
 
5-2 The Phantom Numbering window