Sun Microsystems 120 用户手册

下载
页码 200
8-18
Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
8.5.3
Setting the
alarmon
Software Flag
Set the
alarmon
variable by typing:
where is the number of the alarm you want to turn on: 1, 2, or 3.
8.5.4
Setting the
alarmoff
Software Flag
To set the
alarmoff
configuration variable, type:
where is the number of the alarm you want to turn off: 1, 2, or 3.
8.5.5
Stopping the LOM Sending Event Reports to the
Serial A/LOM port
Set the
event_reporting
variable on by typing:
Note –
This is the equivalent of using the
lom -E on
command from the Solaris
shell (see Chapter 9).
Set the
event_reporting
variable off by typing:
Note –
This is the equivalent of using the
lom -E off
command from the Solaris
shell (see Chapter 9).
lom> set alarmon
n
lom> set alarmoff
n
lom> set eventreporting on
lom> set eventreporting off