Sun Microsystems 120 用户手册

下载
页码 200
9-12
Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
To turn the Fault LED off again, type:
9.3.3
Changing the First Character of the Sequence for
Escaping to the
lom>
Prompt (
lom -X
)
The character sequence #. (hash, dot) enables you to escape from Solaris to the
lom>
prompt.
To change the first character of this default
lom
escape sequence, type:
where is the alpha-numeric character you want to use instead of #.
Note –
If you are at the console and you type the first character of the LOM escape
sequence (by default this is #), there is a second’s delay before the character appears
on the screen. This is because the system waits to see if you type the dot (.) character
next. And, if you do, the
lom>
prompt appears. If you do not, the # character
appears. If you want to change the LOM escape character, use a character that is not
included in many console commands. Otherwise the delay between when you strike
the key and when the character appears on the screen may affect your typing at the
console.
9.3.4
Stopping the LOM from Sending Reports to the
Serial A/LOM Port (
lom -E off
)
LOM event reports can interfere with information you are attempting to send or
receive on the Serial A/LOM port.
To stop the LOM device from sending reports to the Serial A/LOM port, type:
lom -F off
lom -X
x
lom -E off