Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
A.1
Installing a SCSI Hard Disk Drive With
Solaris Running
Before performing the instructions in this section, install the Hard Disk Drive by
following the instructions in Section 4.1, “Installing and Removing Hot-Pluggable
SCSI Hard Disk Drives” on page 4-2.
We recommend you use the instructions below in conjunction with the
cfgadm(M)
man page.
1. With the new Hard Disk Drive physically installed in the drive bay, log into the
system as root and run the
format
command to make the disk visible to the
Operating System.
To do this, type the following (the sample output below is from a system containing
two Hard Disk Drives):
2. Type the following command to find out the label of the new Hard Disk Drive
(this appears in the
Ap_Id
column of the sample output):
In the sample output above, the new disk is Disk 1 (in the server’s outer drive bay).
format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <SUN36G cyl 24427 alt 2 hd 27 sec 107>
/pci@1f,0/pci@1/scsi@8/sd@0,0
1. c0t1d0 <SUN36G cyl 24427 alt 2 hd 27 sec 107>
/pci@1f,0/pci@1/scsi@8/sd@1,0
cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c0::dsk/c0t0d0
CD-ROM
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
c1::dsk/c1t0d0
disk
connected
configured
unknown
c1::dsk/c1t1d0
unavailable
connected
unconfigured
unknown
c2
scsi-bus
connected
unconfigured
unknown