Fujitsu RX330 用户手册
RX330 S1
Operating manual
41
Hardware installation
Installing/removing the server in/from the rack
Installing the telescopic rail with variable support
Figure 5: Fit the left telescopic rail in the PRIMECENTER/DataCenter Rack
Ê
Position the left-hand rail (1) in the support bracket with the vertical lug (a)
in the middle square catch.
in the middle square catch.
Ê
Press the left rail together until its front end passes behind the front left
support upright (2), then release.
support upright (2), then release.
Ê
Secure the rail on the front left support upright (3) and the support bracket
in the rack (4) with two (M5) screws each.
in the rack (4) with two (M5) screws each.
Ê
Repeat the steps with the right telescopic rail (to be secured to the right
support uprights).
support uprights).
Ê
Fit the PRIMECENTER/DataCenter Rack cable management as described
in the technical manual for the rack.
in the technical manual for the rack.
Ê
Insert the server (see the
section).
Ê
Route the cables once the server has been inserted, as described in the
Technical Manual for the rack in question.
Technical Manual for the rack in question.
a
1
4
3
2