Starting up and operation
– System already installed:
Ê
Press the On/Off button (see 
).
The server is switched on, performs a system test and boots the 
operating system.
Switching the server off
The power-on indicator lights up green (item 5 in 
Ê
Shut down the operating system properly.
The server is switched off automatically and goes into standby mode. The 
power-on indicator lights up orange.
I
If the operating system does not switch the server off automatically, press 
the On/Off button for at least four seconds and/or send a corresponding 
control signal.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the 
following ways:
– Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S2, you can configure 
that the server is switched on/off controlled by timer.
– Ring indicator
The server is switched on by an internal or external modem. 
– Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
– After power failure
The server automatically reboots following a power failure (depending on the 
settings in the BIOS or in iRMC S2).
– Power button override
The system can be switched off by pressing and holding down the On/Off 