Appendix A. Advanced Topics 
Appendix A.1.  Data Format 
•  LSB bit in Indication/Control Byte is the1
st 
 status/control value 
•  Suppose Data_Type is ‘Byte’ and only the 1
st
 and 2
nd
 indication status values are 1 (out 
of 8 statuses), all others being zero, Driver will store a numeric value of 3 in Data Array. 
•  Suppose Data_Type is ‘Register’ and only the 1
st
 and 9
th
 indication statuses values are 1 
(out of 16 statuses), all others being zero, Driver will store numeric value of 257 in the 
Data Array. 
•  Suppose  Data_Type  is  ’32-Bit_Reg’  and  only  the  1
st
  9
th 
  and  17
th
  indication  statuses 
values  are  1  (out  of  32  statuses),  all  others  being  zero,  Driver  will  store  the  numeric 
value 65793 in the Data Array.