Fujitsu BX600 S3 用户手册

下载
页码 164
BX600 S3
Operating Manual
13
Preface
Features
Power Supply
Up to four hot-swappable power supply units which adjust automatically to any 
power voltage in the range 200 - 240 V in a 2+2 redundant power supply config-
uration ensure enough power for the system. If one of these units fails, the 
others ensure that operation continues unimpaired. The defective power supply 
unit can be replaced during operation (hot-swap).
Ventilation
The system is kept cool by three fans in each power supply unit and four single 
fans, with two of them mounted one after the other in a housing in the rear 
chassis. This configuration is redundant and hot-swappable.
High Level of Availability and Failure Protection
When memory data is accessed, 1-bit errors in the main memory are recog-
nized and automatically corrected with the ECC (Error Correcting Code) 
method.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in 
the case of an error and automatically “hides” the defective system components.
The PDA (Prefailure Detection and Analyzing) technology from Fujitsu 
Technology Solutions analyzes and monitors all components relevant for 
system reliability.
The hot-swappable components provide additional failure protection. Failure 
protection on a complete blade system is ensured by up to four redundant, hot-
swap power supply units (PSU), as well as hot-swap, redundant fans.
Server Management
Server management is implemented via the supplied 
ServerView
 software and 
PDA (Prefailure Detection and Analyzing) technology from Fujitsu Technology 
Solutions. PDA warns of system errors or overloading before they occur so that 
preventive measures can be taken.
ServerView
 allows the management of all PRIMERGY servers in the network via 
a central console. Here 
ServerView
 supports the following functions:
Remote startup (Wake On LAN)
Temperature monitoring of the CPU and the surrounding area