Fujitsu BX400 S1 用户手册

下载
页码 130
BX400 S1
Operating Manual
17
Introduction
Cooling
Cooling of the system is ensured by two fans in each power supply unit and by 
the fan modules. Each of the fan units contains 2 fans. The fan modules have 
the same aspect ratio as the power supply units. Empty power supply 
installation bays must be fitted with fan modules. The configuration is redundant 
and offers hot-swap functionality (for more information, see 
).
High level of availability and failure protection
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in 
the event of an error and automatically "hides" the defective system 
components.
The PDA (Prefailure Detection and Analyzing) technology from Fujitsu 
Technology Solutions analyzes and monitors all components that are critical for 
system reliability.
The hot-swap components provide additional failure protection. Failure 
protection for the entire system is ensured by four redundant hot-swap power 
supply units as well as redundant hot-swap fans.
Server management
Server management is implemented using the ServerView Operations Manager 
supplied and the PDA (Prefailure Detection and Analysis) technology from 
Fujitsu.  PDA reports the threat of a system error or overload at an early stage, 
allowing preventive measures to be taken.
The ServerView Operations Manager enables the management of all 
PRIMERGY servers in the network via a central console. The ServerView 
Operations Manager supports the following functions:
Round-the-clock monitoring, regardless of server status
High-performance, graphical console bypass (AVR) protected by 
HTTPS/SSL (128 bit)
Remote storage via USB
Remote power on
Temperature monitoring of the CPU and the surrounding area
Detailed status and error reports for processors and main memory