Fujitsu BX400 S1 用户手册

下载
页码 130
BX400 S1
Operating Manual
39
Installing the hardware
4.3
Setting up the floorstand model
I
If you are not installing a PRIMERGY BX400 S1 system unit floorstand 
model, skip this section and continue reading at 
V
CAUTION!
Follow the safety instructions in 
Ê
Transport the system unit to the place where you want to set it up.
Ê
Unpack the system unit (see 
Ê
Set up the system unit. 
V
CAUTION!
– The device must be protected from direct sunlight.
– The essential minimum clearance for servicing must be 
maintained.
– Access to the rear of the system unit must be assured so that 
other devices (e.g. memory subsystems) can be connected.
– A clearance of at least 200 mm must be maintained in front of and 
behind the system to ensure proper ventilation.
– The mains plug must be accessible easily and safely.
Ê
Lock the casters.
Ê
Wire the system unit. Read the information in 
Ê
Connect the system to the mains (see 
).