Global Error indicator (orange)
– Lights up orange if a prefailure event has been detected that 
requires (precautionary) service intervention. 
– Flashes orange if an error was detected that requires service 
intervention.
– Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is activated 
after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System Event 
Log (SEL), in the management blade web interface, on the ServerView 
Local Service Display for Blade, in the ServerView Operations Manager 
or via the iRMC S2's Web interface.
5
CSS indicator (yellow)
– Lights up yellow if a prefailure event was detected for a CSS 
component that you can fix yourself (for reasons of precaution) with 
the CSS concept.
– Flashes yellow if an error was detected that you can fix yourself 
with the CSS concept.
– Does not light up when the system is OK.
If the event is still acute after a power failure, the indicator is activated 
after the restart.
The indicator also lights up in standby mode.
For more information on the CSS concept, see 
.
6
Identification (ID) button with ID LED (blue)
ID indicators on the front and rear of the server light up when the ID 
button is pressed. The two ID indicators are synchronized. To 
deactivate, press the button again.
The ID indicator can also be activated via the management blade web 
interface and via the ServerView Operations Manager and its status 
reported to the ServerView Operations Manager.