Fujitsu BX400 S1 用户手册
62
Operating Manual
BX400
S1
Installation and operation
©
c
o
gni
ta
s.
Ge
se
lls
ch
ft f
ür T
ec
hn
ik
-Do
ku
m
ent
at
io
n
m
b
H 20
09
P
fa
d:
C
:\P
rogr
am
m
e
\F
CT
\t
im
_ap
p\
tim
_l
oc
al
\w
ork
\W
A
LT
E
R
\O
B
J_
DO
K
U
-9
24
6-0
03
.fm
4
Global Error indicator (orange)
– Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
– Flashes orange if an error was detected that requires service
intervention.
– Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is activated
after the restart.
after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System Event
Log (SEL), in the management blade web interface, on the ServerView
Local Service Display for Blade, in the ServerView Operations Manager
or via the iRMC S2's Web interface.
Log (SEL), in the management blade web interface, on the ServerView
Local Service Display for Blade, in the ServerView Operations Manager
or via the iRMC S2's Web interface.
5
CSS indicator (yellow)
– Lights up yellow if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of precaution) with
the CSS concept.
the CSS concept.
– Flashes yellow if an error was detected that you can fix yourself
with the CSS concept.
– Does not light up when the system is OK.
If the event is still acute after a power failure, the indicator is activated
after the restart.
after the restart.
The indicator also lights up in standby mode.
For more information on the CSS concept, see
.
6
Identification (ID) button with ID LED (blue)
ID indicators on the front and rear of the server light up when the ID
button is pressed. The two ID indicators are synchronized. To
deactivate, press the button again.
button is pressed. The two ID indicators are synchronized. To
deactivate, press the button again.
The ID indicator can also be activated via the management blade web
interface and via the ServerView Operations Manager and its status
reported to the ServerView Operations Manager.
interface and via the ServerView Operations Manager and its status
reported to the ServerView Operations Manager.