Operating Manual
71
Installation and operation
Power
Contains power management settings
Power settings (1) (Default values are highlighted):
– Consumption mode (No Consumption Control / Enforced 
Max. Limit / Low Noise Operation / Minimum Power Cons. 
Scheduled Cons. Mode)
– PSU control enabled
– PSU redundancy (No Redundancy / PSU Redundancy / 
Phase Redundancy)
– PSU Dynamic Mode enable (ON / OFF)
Power settings (2):
– Maximum Power Limit (value of "Minimum Power Limit" as 
printed in the same menu)
Power settings (3):
– PSU/Phase Assignment (Unassigned)
– Phase Limit (no value)
PIN
Contains a four-digit PIN as password protection for the 
ServerView Local Service Display for Blade
Default values:
– PIN enabled (OFF)
– PIN (0000)
Check
Ekeying Check: This is a function which allows you to query the 
compatibility of the modules before startup, and then activate, 
partially activate or deactivate the module depending on the 
result. For example, you would not activate modules whose 
operating voltages or power consumption are not compatible with 
the system.
This test begins automatically after switch-on or after a hardware 
replacement. If errors are found, you can find out more about 
them via the Details button. Replace the defective hardware 
component and repeat the test.
Save
Clicking the Save button saves and applies the settings in the 
management blade.
With the Previous button you can go back and change 
parameters. You save the changed configuration with the Save 
button.