Lucent Technologies 555-233-115 用户手册
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-73
High Reliability
5
Resolve Alarms
Examine the alarm log. Resolve any alarms that may exist using
DEFINITY
Enterprise Communications Server Release 8 Maintenance for R8si.
Enable Customer Options and Alarm Origination
to INADS
to INADS
1. Get the DOSS order number of the upgrade from the project manager and
ask the regional Customer Software Administration to complete the steps
in the shaded box. See
in the shaded box. See
for telephone numbers.
NOTE:
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination.
Administrator enables Alarm Origination.
2. When administration is completed, log in as craft at the
Login:
prompt.
"init" login administration:
1. Log in as init.
2. Type change system-parameters customer-options and press
Enter
to verify that the customer options are properly set.
3. Go to screen 6, QSIG Optional Features, and set the
Basic Call
Setup
field to y if the customer was using Supplementary Services
Protocol b or d on an ISDN-PRI trunk group before the upgrade.
4. Type change system-parameters offer-options and press
Enter
.
5. If the
Activate Offer
field is n, set it to y and press
Tab
. A warning
message lets you know whether you need to save translations and
reboot to make the change permanent.
reboot to make the change permanent.
6. Press
Enter
to effect the changes or
Cancel
if there were no changes.
7. Contact the requester when done.