Extensions to TCL 
Various extensions have been incorporated into TCL to support functions to interact with the 
RaritanConsole unit. The command info comm amp (executed in a Script Shell Window) lists all the 
commands that are supported.  
ampsetconfiguration, ampaddsubscription, amprmsubscription, ampsetipacl, amprmipacl, ampadduser, 
amprmuser 
are commands that make configuration changes to the Raritan unit. ampsave must be executed 
in order for the changes to become effective, and may be executed at the end of executing a set of these 
commands or after each command. Please note that in some cases (network), ampsave causes the unit to 
reboot. Use ampreload to revert changes before a save is executed. 
 
ampgetconfiguration
 
Returns a list of categories that can be displayed 
Usage: ampgetconfiguration 
% ampgetconfiguration 
network 
modem 
datacom 
smtp 
radius 
 
If a specific category is specified, then the data for that category will be displayed. 
Usage: ampgetconfiguration <category><port_number> 
  Category:  can be network, datacom, smtp, and radius 
  Port_number: valid port number, applies only to datacom category; otherwise not used 
 
% ampgetconfiguration network 
Hostname: RaritanConsole_C3200 
IP:10.0.1.41 
SubnetMask:255.0.0.0 
Gateway:10.0.1.41 
PortAddress:2398 
TerminalType:VT100 
 
ampsetconfiguration 
Sets the specified field to the value passed.  Returns an error if the interpreter cannot get the config lock. 
Usage: ampsetconfiguration <category> <field_name> <value> 
  Category: network, datacom, smtp, radius 
  Field_name: field to be altered in a particular category 
  Value: new value 
Setting a specific parameter is done as follows (changing a port configuration): 
 
% ampsetconfiguration network portaddress 2398 
configuration successful 
% ampsave 
Important! An ampsave command must be executed in order for any changes to take effect. In the 
instance above, a reboot occurs.