IC Manager provides system administration tools for monitoring alarm events. Visual and 
sometimes auditory alarms (beeps) are triggered whenever the system detects problems that 
require human intervention, such as server failures. Alarms are categorized as Emergency, High, 
Low, or Informational. (For more information about monitoring alarms, refer to 
 
To minimize Alarm Server traffic, alarms that occur repeatedly are gathered by the ADU Server 
and raised periodically. The repeat count indicates how many times the condition has occurred 
since the alarm was last raised.
The following table describes the alarms that are associated with the ADU Server.
Alarm Name
Priority
Description
Cause/Recommended 
Action
AssignFail
Emergency
Cannot Assign to 
ADU%s, ignoring it
Another ADU Server across 
the WAN is unavailable. A site 
has been cut off. WAN 
features may not be available.
BadADUInDS
Emergency
Bad UUID %s in DS’s 
list of ADU servers
Corruption in the DS has made 
it impossible to identify other 
ADU Servers for WAN work. 
Contact Technical Support (1-
800-886-3244).
DumpADU
High
ADU overflow, killing 
eldest
The ADU limit set by the adus 
parameter has been reached. 
The oldest ADUs are being 
removed to make room for 
newer ones.
Increase the value of the adus 
parameter. Determine if ADUs 
are being left in the server 
when they are no longer 
needed, and possibly adjust 
timer settings (nouserinterval, 
idletime).
 (Sheet 1 of 2)