Metrologic Instruments IS4110 用户手册

下载
页码 36
 
 
17
S
CANNER 
T
ERMINATIONS
 
 
IS4125-41 Connector Pin Assignments
 
 
 
Metrologic provides a low profile ZIF 12-pin
 
connector to connect to a 1 mm x 12 position 
FFC/FPC cable. The pin assignments are as follows: 
 
 
Pin
 
Signal Name 
Function 
1 VCC 
Input. 5 VDC (± 0.25V)  
This requires 25 mA in standby and 130 mA peak. 
Ground 
Signal and power ground. 
3 Receive 
Input. RS232 receive data from host.  
Nominal ±12V signals. 
Light Pen 
Source/DTR IN 
Input. Either light pen source voltage (typical:+5VDC) when 
configured for wand emulation or RS232 Data Terminal 
Ready signal from host. Nominal ±12V signals. 
5 RTS 
Output.  
RS232 Ready to send signal from the scan engine. 
Light Pen DATA 
Output. Wand emulation data, open collector output from 
the scan engine. 
7 Transmit 
Output. RS232 transmit data from the scan engine.  
Nominal ±12V signals. 
8 CTS 
Input. RS232 Clear to send signal from host.  
Nominal ±12V signals. 
9* 
Good Read 
Indicator 
Output. 5V high with a 2 kHz pulse. This drain is the pin of a 
PFET type transistor that can source approximately 100 mA 
of current. This output is the connection for an LED or other 
indicator (i.e. beeper+).  It is recommended that the indicator 
is terminated directly to ground. 
10* 
Beeper -  
Input. Collector of an NPN transistor that can sink 
approximately 100 mA of current.  A current limiting pull-up 
resistor and Piezo type transducer (QMB- 111PXN or 
equivalent) is recommended. 
11 Reserved 
Input 
Input. Do not connect to this pin.  This pin is for Metrologic 
internal use only. 
12 LED 
Negative connection for LED. An external pull-up and LED 
is suggested. Maximum current is limited to 25 mA. This line 
is active low when the laser diode is active. 
 
*  Pins 9 and 10 can be used together to form a push-pull type circuit. Pin 9 
becomes the Beeper + and Good - Read source whereas Pin 10 supplies the 
pathway to ground..  
 
Figure 7 
1
12