Symbol MS4404/MS4407 Integration Guide
Simple Serial Interface Default Parameters
This section describes how to set up the decoder with a SSI host. When SSI is used, the decoder is programmed 
via bar code menu or SSI hosts commands.
Throughout the programming bar code menus, default values are indicated with asterisks (
*
).
 lists the defaults for the SSI host. There are two ways to change the default values:
Scan the appropriate bar codes in this guide. These new values replace the standard default values in 
memory. To recall the default parameter values, scan the 
 bar code on
Download data through the device’s serial port using SSI. Hexadecimal parameter numbers are shown in this 
chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar 
codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing 
parameters using this method.
*
Baud Rate 9600
(06h)
Feature/Option
*
 Indicates Default
Option Hex Value for programming 
via SSI command
NOTE
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the 
screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and 
bars and/or spaces are not merging.
NOTE
See 
 for all user preferences, hosts, symbologies, and miscellaneous 
default parameters.
Table 8-3    
SSI Default Table
Parameter
Parameter 
Number
Default
Page 
Number
Select SSI Host
N/A
N/A
Baud Rate
9Ch
9600
Parity
9Eh
None
Check Parity
97h
Disable
Software Handshaking
9Fh
ACK/NAK
Host RTS Line State
9Ah
Low
Decode Data Packet Format
EEh
Send Raw Decode Data
Stop Bits 
9Dh
1