Motorola MS4404 用户手册

下载
页码 310
11 - 36 Symbol MS4404/MS4407 Integration Guide
Code 11
Code 11
Parameter # 0Ah
To enable or disable Code 11, capture the appropriate bar code below. 
Set Lengths for Code 11
Parameter # L1 = 1Ch, L2 = 1Dh
The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) 
the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific 
range.
One Discrete Length - Select this option to decode only Code 11 symbols containing a selected length. 
Select the length using the numeric bar codes in 
. For example, to decode 
only Code 11 symbols with 14 characters, capture Code 11 - One Discrete Length, then capture followed 
by 4. To correct an error or to change the selection, capture Cancel on
Two Discrete Lengths - Select this option to decode only Code 11 symbols containing either of two 
selected lengths. Select lengths using the numeric bar codes in 
. Fo
example, to decode only those Code 11 symbols containing either 2 or 14 characters, select Code 11 - Two 
Discrete Lengths
, then capture 02, 1, and then 4. To correct an error or to change the selection, 
capture Cancel on
.
Length Within Range - Select this option to decode a Code 11 symbol with a specific length range. 
Select lengths using numeric bar codes in 
For example, to decode 
Code 11 symbols containing between 4 and 12 characters, first capture Code 11 - Length Within Range
Then capture 041, and 2 (single digit numbers must always be preceded by a leading zero). To correct an 
error or change the selection, capture Cancel on
Any Length - Capture this option to decode Code 11 symbols containing any number of characters within 
the imager capability. 
Enable Code 11
(01h)
*
Disable Code 11
(00h)