Motorola MS4404 用户手册

下载
页码 310
Symbologies 11 - 73
Redundancy Level
Parameter # 4Eh
The imager offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar 
code quality. As redundancy levels increase, the imager’s aggressiveness decreases.
Select the redundancy level appropriate for the bar code quality.
Redundancy Level 1
The code types in 
 must be successfully read twice before being decoded:
Redundancy Level 2
The code types in 
 must be successfully read twice before being decoded:
Redundancy Level 3
Code types other than the code types in 
 must be successfully read twice before being decoded. The 
following codes must be read three times:
Table 11-2    
Redundancy Level 1
Code Type
Code Length
Codabar
8 characters or less
MSI
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Table 11-3    
Redundancy Level 2
Code Type
Code Length
All
All
Table 11-4    
Redundancy Level 3
Code Type
Code Length
MSI Plessey
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Codabar