All programmed rules are stored in a buffer. As they are programmed, they are stored at 
the “top” of a rules list. If three rules have been created, the list would be configured as 
follows:
Third Rule
Second Rule
First Rule
When data is scanned, the rules list is checked from top to bottom to determine if the criteria 
matches (and therefore, if the actions should occur). Input is modified into the data format 
specified by the first matching set of criteria it finds. Be sure that your most general rule is 
the last one programmed. 
For example, if the THIRD rule states:
When scanning a bar code of any length, send all data, then send the ENTER key.
And the SECOND rule states:
When scanning a Code 128 bar code of length 12, send the first four characters, 
then send the ENTER key, then send all remaining data.
If a Code 128 bar code of length 12 were scanned, the THIRD rule would be in effect. The 
SECOND rule would appear to not function.
Note also that ADF rules are actually created when you use the standard data editing 
functions. Scan options are entered as ADF rules, and the hierarchy mentioned above also 
applies to them. For the Symbol  LS9208, this applies to prefix/suffix programming in the 
parameter Scan Data Transmission Format.
These rules reside in the same “rule list” as ADF Rules, so the order of their creation is also 
important.
Default Rules
Every unit has a default rule to send all scan data. Units with custom software may have 
one or more default rules burned in. The rules hierarchy checks user programmable rules 
first, then the default rules. Default rules can be disabled by entering the following general 
rule in the user programmable buffer:
When receiving scan data, send all data.
Since this rule always applies, ADF will never go into the default rules.