Using the Roborun Configuration Utility
198
AX3500 Motor Controller User’s Manual
 Version 1.9b. June 1, 2007
Operating the AX3500 over a Wired or Wireless LAN
The Roborun utility supports connection and operation of the AX3500 controller over a 
Wired or Wireless TCP/IP network. This feature makes it easy to tele-operate and monitor 
the controller across a lab or across the globe via Internet.
To operate over the network, two computers are required, as show in Figure 111 below. 
The top computer is connected to the controller via its COM port. Both computers are con-
nected to a TCP/IP network. 
The computer connected to the controller must run a communication server program 
named Roboserver. This program is automatically installed in the Start menu when install-
ing the Roborun utility. This program’s function it to wait for and accept TCP/IP connection 
requests from the other computer and then continuously move data between the network 
and the COM port. When launched, the screen shown below appears.
The second computer runs the Roborun utility. To establish contact with the server pro-
gram, click on the “Change COM/LAN Port” button and enter the IP address of the second 
computer. Communication should be established immediately.
When the two computers are connected, it will be possible to operate the motors and read 
the controller’s operating parameters in the Roborun Run window.
Wired or 
Wireless 
802.11 LAN
Computer running
Roborun Utility
Computer running
Roboserver
Controller
FIGURE 111. Operating the controller over a LAN