Connecting and Using the Encoder Function
84
AX3500 Motor Controller User’s Manual
 Version 1.9b. June 1, 2007
In Single Channel Mode, limit switches 3 and 4 are used. This is to allow direct connection 
of an encoder on the inputs for channel 1 and direct connection of switches on the inputs 
for channel 2
Using the Encoder Module to Measure Distance
As the encoders rotate, their quadrature outputs is automatically processed and incre-
ments/decrements two 32-bit counter inside the Encoder Module. There is one 32-bit 
counter for each of the encoders.
The counter values are stored as a signed binary numbers, ranging from   -2,147,836,648 to 
+2,147,836,647 (Hexadecimal format of value 80000000 to 7FFFFFFF respectively. When 
the maximum or minimum counter values are reached, the counters automatically roll over 
to zero.
Using the Encoder to Measure Speed
The encoder module will automatically compute rotation speed for each encoder. The 
resulting measured speed is a value ranging from 0 to + 127 and 0 to -127, where 127 rep-
resent a relative ratio of a maximum speed value chosen by the user. 
For example, if the encoder module is configured so that the highest measured speed 
value is 3,000 RPM, then a reading of 63 (127/2) would be 1,500 RPM. 
TABLE 16. Effects of Limit Switches 3 and 4 on Motor 2
SW3
SW4
Motor 2 Fwd
Motor 2 Rev
OFF
OFF
Allowed
Allowed
ON
OFF
Stopped
Allowed
OFF
ON
Allowed
Stopped
ON
ON
Stopped
Stopped
TABLE 17. Effects of Limit Switches 3 and 4 on Motor 2 in Single Channel Configuration
SW3
SW4
Motor Fwd
Motor Rev
OFF
OFF
Allowed
Allowed
ON
OFF
Stopped
Allowed
OFF
ON
Allowed
Stopped
ON
ON
Stopped
Stopped