RoboteQ AX3500 用户手册
AX3500 Motor Controller Overview
28
AX3500 Motor Controller User’s Manual
Version 1.9b. June 1, 2007
•
60A up to 15 seconds (per channel)
•
50A up to 30 seconds
•
40A extended
•
High current operation may be extended with forced cooling
•
250A peak Amps per channel
•
16kHz Pulse Width Modulation (PWM) output
•
Auxiliary output for brake, clutch or armature excitation
•
Heat sink on PCB
•
Optional Bottom Aluminum place for conduction cooling (BP version)
Advanced Safety Features
•
Safe power on mode
•
Optical isolation on R/C control inputs
•
Automatic Power stage off in case of electrically or software induced program fail-
ure
ure
•
Overvoltage and Undervoltage protection
•
Regeneration current limiting
•
Watchdog for automatic motor shutdown in case of command loss (R/C and RS232
modes)
modes)
•
Large, bright run/failure diagnostics on 7 segment LED display
•
Programmable motor acceleration
•
Built-in controller overheat sensor
•
Emergency Stop input signal and button
Data Logging Capabilities
•
13 internal parameters, including battery voltage, captured R/C command, tempera-
ture and Amps accessible via RS232 port
ture and Amps accessible via RS232 port
•
Data may be logged in a PC, PDA or microcomputer
Compact Open Frame PCB Design
•
Surface mount PCB design
•
Efficient heat sinking. Operates without a fan in most applications.
•
6.75” (171.5mm) long x 4.20” (106.7mm) wide
•
-20o to +85o C heatsink operating environment
•
7.5oz (220g)