Bosch 3922 988 43318 用户手册

下载
页码 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 10 - Installation Techniques
en | 10-10
Control Capacity
10.5   Control Capacity
The Central Control Unit LBB 3500/05 has a power handling capacity to power up to 90 DCN units, 
while Central Control Units LBB 3500/15 and LBB 3500/35 have a power handling capacity to power 
up to 180 DCN units. However, the built-in ‘control facilities’ of all CCUs are capable of controlling up 
to a maximum of 240 active units* and an unlimited number of passive units**.  A combination of 
both active and passive units can be connected to any system ‘tap-off ’ or trunk-line outlet connector.
Where more than 240 active units are required, the DCN system can be extended with the Multi-
Central Control unit LBB 3500/35 for use in Multi-CCU systems. In combination with a dedicated PC, 
fitted with a Multi-PC- card LBB 3511/00 and Multi-CCU software LBB 3586/00, the PC can control 
up to a maximum of 16 CCU’s connected in a 75 ohm coaxial loop-through chain. Each CCU in the 
chain has the same Power handling and control capacity as the Extended CCU (LBB 3500/15).           
In total, a maximum of 3,840 active units, using sixteen LBB 3500/35 type CCU’s can be controlled.
* Active (contribution) units include:
LBB 3530/xx, LBB 3531/xx,  ...............................................................Delegate discussion units
LBB 3533/xx, LBB 3534/xx .................................................................Chairman discussion units
LBB 3544/00, LBB 3545/00, LBB 3546/00, LBB 3547/00 ..Conference units (Concentus)
LBB 3520/10 ................................................................................................Interpreter desk
LBB 3535/00 ................................................................................................Dual Audio Interface Unit (See Note 1)
LBB 3540/00 ................................................................................................Multi-purpose Connection Unit
LBB 3512/00 ................................................................................................Data Distribution Board
LBB 3510/00 ................................................................................................PC Network Card
LBB 3513/00 ................................................................................................Analog Audio Input/Output Module
**Passive (distribution) units include:
LBB 3524/xx/, LBB 3526/10 ............................................................Channel Selector Panel (See Note 2)
NOTE 1: 
The Dual Audio Interface Unit is controlled by the system as a single active unit, 
however two microphone inputs can be individually switched on or off.  Therefore, when 
using the Dual Audio Interface Unit LBB 3535/00, up to a maximum of 480 microphones 
can be connected to a single Central Control Unit.
NOTE 2:
 Up to 10,000 Channel Selector Panels LBB 3524/xx and LBB 3526/xx can be 
connected to a single Central Control Unit in combination with Extension power supply 
units and/or Audio Media Interface Units to provide the required power.
10.6   Stand-alone Systems                                                    
(using Extension cables,  Trunk-splitter and Tap-off units)
All DCN system units are connected to the CCU  via its three outlet trunk-line cable connectors.
10.6.1  Basic System (without extension units)
 shows a basic trunk-line interconnection, without extension units.
FIG 10-13 System Interconnection without extension unit
Port 1
Rec.
Line
In
Out
In
Out
Symmetrical
Trunk
115 V-T4A  230 V -T2A
Port 1
Port 2
Rec.
Line
In
Out
In
Out
Symmetrical
Trunk
115 V-T4A  230 V -T2A
Central Control Unit
Central Control Unit
LBB 3500/05
LBB 3500/15 
 90 PCF (max.)
 180 PCF (max.)