10.8 Multi-CCU system
Multi-CCU caters for situations where more than 240 contribution units are required. Multi-CCU
systems are controlled from a separate, dedicated PC running OS.2 version 3.00 Warp operating
system, the Multi-CCU software (LBB 3586) and equipped with the LBB 3511/00 Network/Multi-
CCU card. All Multi-CCU units and the LBB 3511/00 are interconnected via a closed loop.
systems are controlled from a separate, dedicated PC running OS.2 version 3.00 Warp operating
system, the Multi-CCU software (LBB 3586) and equipped with the LBB 3511/00 Network/Multi-
CCU card. All Multi-CCU units and the LBB 3511/00 are interconnected via a closed loop.
shows a typical Multi-CCU configuration, for connection of up to a maximum of 16 LBB 3500/35
CCU’s.
CCU’s.
10.8.1 Multi-CCU and PC interconnection
. DCN Control using Personal Computers.
WARNING:
Before connecting the computer or the CCU’s to the Multi-CCU cabling,
ensure that the mains supply is off on all units, and the voltage selection switch on the
computer is set for the correct mains voltage.
computer is set for the correct mains voltage.
Using the Multi-CCU BNC cables, connect the Multi-CCU card’s OUT-port to the first CCU’s IN-
port. The next CCU’s IN-port must be connected to the previous CCU’s OUT-port. The OUT-port
of the final CCU must be connected to the Multi-CCU card’s IN-port (see
port. The next CCU’s IN-port must be connected to the previous CCU’s OUT-port. The OUT-port
of the final CCU must be connected to the Multi-CCU card’s IN-port (see
). The
interpreter desks can be connected to any CCU if the Multi-CCU mode is selected. However it is
recommended to connect all interpreter desks to one and the same CCU.
recommended to connect all interpreter desks to one and the same CCU.
NOTES:
1.Ensure that the Multi-CCU cabling is always connected from an OUT-port of a unit to an
IN-port of another unit.
2.The maximum cable length between interconnected CCUs is 100 m. (328 ft.):
1. Checking the Multi-CCU link
When the Multi-CCU link is operating correctly, the Error LEDs of all interconnected CCU’s are off. If
not (i.e. error LEDs on), check the interconnections and unit settings.
not (i.e. error LEDs on), check the interconnections and unit settings.
2. Installing the Multi-CCU software package LBB 3586/00
Information on how to install the Multi-CCU software, can be found in the DCN Software User’s
Manual delivered with software package LBB 3586/00.
Manual delivered with software package LBB 3586/00.
NOTE:
For address selection
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Port 1
Port 2
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
In
Out
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
Mult-CCU
Trunk
115 V-T4A 230 V -T2A
Rec.
Line
In
Out
In
Out
Symmetrical
In
Out
1
2
3
8
15
14
9
Port 1
Port 2
Port 1
Port 2
Port 1
Port 2
Port 1
Port 2
Port 1
Port 2
Port 1
Port 2
Port 1
Port 2
PC dedicated for Multi-CCU’s
UPS (Uninterrupted Power Supply) recommended
Multi-CCU Software LBB 3586 and OS.2
PC Network card (LBB 3511/00)
75 Ohm coax cable (RG 59)
LBB 3500/35
LBB 3500/35
LBB 3500/35
LBB 3500/35
LBB 3500/35
LBB 3500/35
LBB 3500/35
LBB 3500/35
≤
180 PCF
≤
180 PCF
≤
180 PCF
≤
180 PCF
≤
180 PCF
≤
180 PCF
≤
180 PCF
≤
180 PCF
16 (max)