Chapter 45      Troubleshooting
Using TDR
To end a trace in progress, enter the escape sequence (Ctrl-^ X by default). Simultaneously press and 
release the CtrlShift, and 6 keys and then press the X key. 
Using TDR
These sections contain this information:
Understanding TDR
You can use the Time Domain Reflector (TDR) feature to diagnose and resolve cabling problems. When 
running TDR, a local device sends a signal through a cable and compares the reflected signal to the initial 
signal. 
TDR is supported only on 10/100/1000 copper Ethernet ports. It is not supported on 10-Gigabit Ethernet 
ports and on SFP module ports.
TDR can detect these cabling problems:
Open, broken, or cut twisted-pair wires—The wires are not connected to the wires from the remote 
device.
Shorted twisted-pair wires—The wires are touching each other or the wires from the remote device. 
For example, a shorted twisted pair can occur if one wire of the twisted pair is soldered to the other 
wire.
If one of the twisted-pair wires is open, TDR can find the length at which the wire is open.
Use TDR to diagnose and resolve cabling problems in these situations:
Replacing a switch
Setting up a wiring closet
Troubleshooting a connection between two devices when a link cannot be established or when it is 
not operating properly
Table 45-2
Traceroute Output Display Characters
Character
Description
*
The probe timed out.
?
Unknown packet type.
A
Administratively unreachable. Usually, this output means that an access list is 
blocking traffic.
H
Host unreachable.
N
Network unreachable.
P
Protocol unreachable.
Q
Source quench.
U
Port unreachable.