PMC-Sierra PM5358 S/UNI 4x622 用户手册

下载
页码 136
PM5358 S/UNI-4x622 Driver Manual
Application Programming Interface
Proprietary and Confidential to PMC-Sierra, Inc.
65
Document ID: PMC-2010419, Issue 1
SUNI4x622_ERR_INVALID_ARG
Valid States
SUNI4x622_ACTIVE, SUNI4x622_INACTIVE
Side Effects
None
Configuring SD Error Monitor: suni4x622LOHSDCfg
This function configures the Signal Defect BERM automatic monitoring of line bit error rate
threshold events.
Prototype
INT4 suni4x622LOHSDCfg(sSUNI4x622_HNDL deviceHandle,
UINT1 channel, sSUNI4x622_CFG_SD *psdcfg)
Inputs
deviceHandle
: device handle (from 
suni4x622Add
)
channel
: channel number
psdcfg
: (pointer to) SD configuration block
Outputs
None
Returns
Success = 
SUNI4x622_SUCCESS
Failure = 
SUNI4x622_ERR_INVALID_DEVICE_STATE
               
SUNI4x622_ERR_INVALID_DEV
               
SUNI4x622_ERR_INVALID_CHAN
SUNI4x622_ERR_INVALID_ARG
Valid States
SUNI4x622_ACTIVE, SUNI4x622_INACTIVE
Side Effects
None
Writing the K1K2 Byte: suni4x622LOHWriteK1K2
This function writes the K1, K2 byte into the line overhead.
Prototype
INT4 suni4x622LOHWriteK1K2(sSUNI4x622_HNDL
deviceHandle, UINT1 channel, UINT1 K1, UINT1 K2)
Inputs
deviceHandle
: device handle (from 
suni4x622Add
)
channel
: channel number
K1
: K1 byte to write
K2
: K2 byte to write
Outputs
None
Returns
Success = 
SUNI4x622_SUCCESS
Failure = 
SUNI4x622_ERR_INVALID_DEVICE_STATE
               
SUNI4x622_ERR_INVALID_DEV
               
SUNI4x622_ERR_INVALID_CHAN
Valid States
SUNI4x622_ACTIVE, SUNI4x622_INACTIVE