Intel SERVER CHASSIS SR2500 SR2500 用户手册

产品代码
SR2500
下载
页码 115
Intel® Server System SR2500AL 
Environmental and  Regulatory Specifications 
Revision – 1.00 
 
 
Intel order number D31980-004 
81
 
 
 
10.  Environmental and  Regulatory Specifications 
10.1  System Level Environmental Limits 
The table below defines the system level operating and non-operating environmental limits  
Table 55. System Environmental Limits Summary 
 Parameter  
Limits 
Operating Temperature 
+10
°C to +35°C with the maximum rate of change not to exceed 10°C per hour 
Non-Operating 
Temperature 
-40
°C to +70°C 
Non-Operating Humidity 
90%, non-condensing @ 28
°C 
Acoustic noise  
Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient 
temperature. (23 +/- degrees C) Sound Power: 7.0 BA in an idle state at typical 
office ambient temperature. (23 +/- 2 degrees C) 
Shock, operating 
Half sine, 2 g peak, 11 mSec 
Shock, unpackaged 
Trapezoidal, 25 g, velocity change 136 inches/sec 
Shock, packaged 
Non-palletized free fall in height 24 inches (≧40 lbs to < 80 lbs) 
Vibration, unpackaged 
5 Hz to 500 Hz, 2.20 g RMS random 
Shock, operating 
Half sine, 2 g peak, 11 mSec 
ESD 
+/-15kV except I/O port +/-8KV per Intel Environmental test specification 
System Cooling 
Requirement in BTU/Hr 
1826 BTU/hour 
 
10.2  Product Regulatory Compliance 
10.2.1 
Product Safety Compliance 
The Intel
® 
Server Chassis SR2500 complies with the following safety requirements: 
•  UL60950 – CSA 60950(USA / Canada) 
•  EN60950 (Europe)  
• IEC60950 
(International) 
•  CB Certificate & Report, IEC60950 (report to include all country national deviations) 
•  GS License (Germany)  
•  Belarus License (Belarus) 
•  Ukraine License (Ukraine) 
•  CE - Low Voltage Directive 73/23/EEE (Europe)  
•  IRAM Certification (Argentina)  
•  GB4943- CNCA Certification (China)