Installation 
8
309463N
Installation
General Information
Grounding
1.
Pump: use Part No. 238909 Ground Wire and 
Clamp (supplied). See F
IG
. 1. Insert one end of the 
ground wire (Y) into the pump’s grounding clamp (X) 
and tighten the screw (W) securely. Connect the 
other end of the wire to a true earth ground. 
2.
Air and fluid hoses: use only electrically conductive 
hoses.
3.
Air compressor: follow manufacturer's recommen-
dations.
4.
Spray gun: ground through connection to a properly 
grounded fluid hose and pump.
5.
Fluid supply container: follow your local code.
6.
Object being sprayed: follow your local code.
7.
Solvent pails used when flushing: follow your local 
code. Use only metal pails, which are conductive, 
placed on a grounded surface. Do not place the pail 
on a nonconductive surface, such as paper or card-
board, which interrupts the grounding continuity.
8.
To maintain grounding continuity when flushing or 
relieving pressure,
 hold a metal part of the spray 
gun firmly to the side of a grounded metal pail, then 
trigger the gun.
Install the Muffler
The muffler (C, F
IG
. 2) is shipped loose. Screw the muf-
fler into the muffler port before installing the pump.
Air and Fluid Hoses
See F
IG
. 2. Be sure all air hoses (A, P) and fluid hoses 
(R, U) are properly sized and pressure-rated for your 
system. Use only electrically conductive hoses. Fluid 
hoses must have spring guards on both ends. Use a 
swivel (S) between the fluid hose (R) and the gun (T) to 
allow easier gun movement.
Reference numbers and letters in parentheses 
in the text refer to the callouts in the figures 
and the parts drawing.
Always use 
G
enuine Graco Parts and Acces-
sories, available from your Graco distributor. If 
you supply your own accessories, be sure they 
are adequately sized and pressure-rated for 
your system.
F
IG
. 2 is a guide for selecting and installing 
system components and accessories. It is not 
an actual system design. Contact your Graco 
distributor for assistance in designing a system 
to suit your particular needs.
WARNING
Before operating the pump, ground the system as 
explained below. Read the warnings on page 6.
F
IG
. 1. Grounding Wire
ti1930a
Y
X
W
TI1102
TI1102