Troubleshooting
3A0157B
13
Electrical
Symptom: Sprayer does not run or stops running.
Perform Pressure Relief Procedure; page 8.
Plug sprayer into correct voltage, grounded outlet
Set power switch OFF for 30 seconds and then ON 
again (this ensures sprayer is in normal run mode).
Turn pressure control knob clockwise 1/2 turn
View digital display
WARNING
If no digital display is available, use control 
board status light to troubleshoot prob-
lems: Turn ON/OFF switch OFF, remove 
control cover and then turn power back 
ON. Observe status light. Blinking LED to-
tal count equals digital error code i.e., two 
blinks equals E=02.
To avoid electrical shock or moving parts hazards when 
covers are removed for troubleshooting, wait 30 sec-
onds after unplugging power cord for stored electricity 
to dissipate. Keep clear of electrical and moving parts 
during troubleshooting procedures.
TYPE OF PROBLEM
WHAT TO CHECK
HOW TO CHECK
Sprayer does not run at all
See flow chart, page 19.
Digital display is blank
Control board status light never 
lights
Sprayer does not run at all
Check transducer or transducer 
connections
1.
Make sure there is no pressure in the system (see 
Pressure Relief Procedure, page 8). Check fluid 
path for clogs, such as clogged filter.
2.
Use airless paint spray hose with no metal braid 
1/4 in. x 50 ft minimum. Smaller hose or metal braid 
hose may result in high-pressure spikes.
3.
Set sprayer to OFF and disconnect power to 
sprayer. 
4.
Check transducer and connections to control board.
5.
Disconnect transducer from control board socket. 
Check that transducer and control board contacts 
are clean and secure.
6.
Reconnect transducer to control board socket. 
Connect power, set sprayer ON and control knob 
1/2 turn clockwise. If sprayer does not run properly, 
set sprayer to OFF and go to next step.
7.
Install new transducer. Connect power, set sprayer 
ON and control knob 1/2 turn clockwise. Replace 
control board if sprayer does not run properly.
Digital display shows E=02
Control board status light blinks 
2 times repeatedly